RFM23 Datasheet, PDF (7/152 Pages) – | |||
|
◁ |
RFM23
Table 4. Transmitter AC Electrical Characteristics1
Parameter
TX Frequency Range1
FSK Modulation Data Rate2
OOK Modulation Data
Rate2
Modulation Deviation1
Modulation Deviation
Resolution
Output Power Range1
Symbol
FSYNTH-LB
FSYNTH-HB
DRFSK
DROOK
Îf
ÎfRES
PTX
Conditions
Low Band
High Band
Min Typ Max Units
240
â 480 MHz
480
â 930 MHz
1
â 128 kbps
1.2
â
40 kbps
Production tests maximum
limit of 320 kHz
±0.625
±320 kHz
â 0.625 â kHz
Power control by txpow[2:0] Register
Production test at txpow[2:0] = 111
â8
Tested at 915 MHz
â +13 dBm
Max Output Power
PTX_max
Tested at 315-915 MHz
+11 +13 â dBm
TX RF Output Steps2
P â³ RF_OUT
controlled by txpow[2:0] Register
â
3
â dB
TX RF Output Level
Variation vs. Voltage2
ï®PRF_V
Measured from VDD=3.6 V to
VDD=1.8 V
â
2
â dB
TX RF Output Level2
P â³ RF_TEMP
Variation vs. Temperature
â40 to +85â
â
2
â dB
TX RF Output Level
Variation vs. Frequency2
P â³ RF_FREQ
Measured across any one
frequency band
â
1
â dB
Transmit Modulation
Filtering2
Gaussian Filtering Bandwith Time
B*T
â
0.5 â
Product
Spurious Emissions2
POB-TX1
POUT = 11 dBm,
Frequencies <1 GHz
â
â â54 dBm
POB-TX2 1â12.75 GHz, excluding harmonics
â
â â54 dBm
Notes:
1. All specification guaranteed by production test unless otherwise noted.
2. Guaranteed by qualification.
7
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com
|
▷ |