English
Language : 

RFM23 Datasheet, PDF (106/152 Pages) –
RFM23
Register 31h. EZMAC® Status
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name Reserved rxcrc1
pksrch
pkrx
pkvalid
crcerror
pktx
pksent
Type
R
R
R
R
R
R
R
Reset value = 00000000
Bit
Name
7
Reserved
6
rxcrc1
5
pksrch
4
pkrx
3
pkvalid
2
crcerror
1
pktx
0
pksent
Function
Reserved.
If high, it indicates the last CRC received is all one’s.
May indicated Transmitter underflow in case of CRC error.
Packet Searching.
When pksrch = 1 the radio is searching for a valid packet.
Packet Receiving.
When pkrx = 1 the radio is currently receiving a valid packet.
Valid Packet Received.
When a pkvalid = 1 a valid packet has been received by the receiver. (Same bit
as in register 03, but reading it does not reset the IRQ)
CRC Error.
When crcerror = 1 a Cyclic Redundancy Check error has been detected. (Same
bit as in register 03, but reading it does not reset the IRQ)
Packet Transmitting.
When pktx = 1 the radio is currently transmitting a packet.
Packet Sent.
A pksent = 1 a packet has been sent by the radio. (Same bit as in register 03,
but reading it does not reset the IRQ)
106