English
Language : 

HMC6352 Datasheet, PDF (2/13 Pages) Honeywell Solid State Electronics Center – Digital Compass Solution
HMC6352
HMC6352 SPECIFICATIONS
Characteristics
Conditions (1)
Min
Typ
Max
Supply Voltage
Vsupply to GND
2.7
3.0
5.2
Supply Current
Vsupply to GND
Sleep Mode (Vsupply = 3.0V)
1
Steady State (Vsupply = 3.0V)
1
Steady State (Vsupply = 5.0V)
2
10
Dynamic Peaks
Field Range (2)
Total applied field
0.10
-
0.75
Heading Accuracy
HMC6352
2.5
Heading Resolution
0.5
Heading
1.0
Repeatability
Disturbing Field
Sensitivity starts to degrade.
20
Enable set/reset function to restore sensitivity.
Max. Exposed
Field
No permanent damage and set/reset function
restores performance.
10000
Operating
Ambient
-20
70
Temperature
Storage
Ambient
-55
125
Temperature
Peak Reflow
For Lead-Free SMT Reflow
230
-
240
Temperature
Moisture Sensivity
Max 240°C
MSL3
Output
Heading, Mag X, Mag Y
Size
6.5 x 6.5 x 1.5
Weight
0.14
(1) Tested at 25°C except stated otherwise.
(2) Field upper limit can be extended by using external resistors across CA1/CA2 and CB1/CB2.
Units
Volts
µA
mA
mA
mA
gauss
degRMS
deg
deg
gauss
gauss
°C
°C
°C
-
mm
grams
Pin Configuration/Package Dimensions
2