English
Language : 

NSCDNNN015PAUNV Datasheet, PDF (4/12 Pages) Honeywell Accelerometers – TruStability® Board Mount Pressure Sensors: NSC Series–Uncompensated/Unamplified
Figure 1. Nomenclature and Order Guide
NSC _ _ _ N _ _ _ _ _ U N V
Series
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Pressure Port (* indicates not available)
DIP
SMT
NN = No ports
NN = No ports
*
AN = Single
axial barbed
port
LN = Single
axial barbless
port
*
*
AN = Single
axial barbed
port
LN = Single
axial barbless
port
*
*
*
*
*
*
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
*
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
DR =Dual radial
barbed ports,
opposite sides
*
*
*
*
*
*
*
*
SIP
NN = No ports
AA = Dual axial
barbed ports,
opposite sides
AN = Single
axial barbed
port
LN = Single
axial barbless
port
FF = Fastener
mount, dual axial
barbed ports,
opposite sides
FN = Fastener
mount, single axial
barbed port
GN = Ribbed
fastener mount,
single axial
barbed port
NB = Fastener
mount, dual axial
ports, same side
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
HH = Fastener
mount, dual
radial barbed
ports, same side
HN = Fastener
mount, single
radial barbed
port
MN = Manifold
mount, outer
diameter seal
SN = Manifold
mount, inner
diameter seal
Note:
9. See Table 5 for an explanation of sensor pressure types.
4
www.honeywell.com/sensing
Supply Voltage
V = Constant
Compensation
N = Uncompensated
Amplification
U = Unamplified
Pressure Range9
1 psi to 150 psi
60 mbar to 10 bar
Absolute
015PA = 0 psi to 15 psi
030PA = 0 psi to 30 psi
060PA = 0 psi to 60 psi
100PA = 0 psi to 100 psi
150PA = 0 psi to 150 psi
Differential
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
060PD = ±60 psi
100PD = ±100 psi
150PD = ±150 psi
Gage
001PG = 0 psi to 1 psi
005PG = 0 psi to 5 psi
015PG = 0 psi to 15 psi
030PG = 0 psi to 30 psi
060PG = 0 psi to 60 psi
100PG = 0 psi to 100 psi
150PG = 0 psi to 150 psi
Absolute
001BA = 0 bar to 1 bar
1.6BA = 0 bar to 1.6 bar
2.5BA = 0 bar to 2.5 bar
004BA = 0 bar to 4 bar
006BA = 0 bar to 6 bar
010BA = 0 bar to 10 bar
Differential
060MD = ±60 mbar
100MD = ±100 mbar
160MD = ±160 mbar
250MD = ±250 mbar
400MD = ±400 mbar
600MD = ±600 mbar
001BD = ±1 bar
1.6BD = ±1.6 bar
2.5BD = ±2.5 bar
004BD = ±4 bar
006BD = ±6 bar
010BD = ±10 bar
Gage
060MG = 0 mbar to 60 mbar
100MG = 0 mbar to 100 mbar
160MG = 0 mbar to 160 mbar
250MG = 0 mbar to 250 mbar
400MG = 0 mbar to 400 mbar
600MG = 0 mbar to 600 mbar
001BG = 0 bar to 1 bar
1.6BG = 0 bar to 1.6 bar
2.5BG = 0 bar to 2.5 bar
004BG = 0 bar to 4 bar
006BG = 0 bar to 6 bar
010BG = 0 bar to 10 bar
Options
N = No special options