FEATURES AND BENEFITS (=competitive differentiator) (continued)
 Industry-leading flexibility:
Extremely low power consumption (operating supply voltage
Modular, flexible design with numerous package
as low as 1.8 Vdc):
styles, pressure ports, and options simplify
Reduces power consumption
integration into the device manufacturer’s application
Provides extended battery life
Single side wet media option allows the end
Promotes energy efficiency
customer to use one port of the sensor with
condensing humidity or directly with non-corrosive
liquid media
 Small size: Miniature 10 x 10 mm [0.39 x 0.39 in]
package is very small when compared to most board
mount pressure sensors
Occupies less area on the PCB
Typically allows for easy placement on crowded
PCBs or in small devices
 Repeatability: Provides excellent repeatability, high
accuracy and reliability under many demanding
Low operating voltage
Sensitive: Meets specified pressure level requirements,
providing enhanced sensitivity and accuracy over the range
Virtually insensitive to mounting orientation, allowing for
flexibility of use with the application
Ratiometric analog output
Infinite resolution
Fast response time
RoHS compliant
Absolute, differential and gage types
conditions
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
Also available in the HSC Series and the SSC Series which
are fully compensated and calibrated with amplified analog or
digital I2C or SPI outputs
POTENTIAL APPLICATIONS (=focus applications)
Medical:
Respiratory breathing circuits:
Nebulizers
Spirometers
Patient monitoring
Flow/pressure control:
Therapeutic hospital beds
Gas collection/delivery:
 Hospital gas supply
Oxygen concentrators
Precise sampling/gas flow:
 Blood analysis
 Gas chromatography
 Analytical instrument sampling systems
Industrial:
Pneumatic components:
 Valves
 Pumps
 Actuators
Pneumatic systems:
 HVAC transmitters
 Automated pneumatic assembly equipment
 Pneumatic operator control systems
Gas collection/delivery:
 Industrial gas supply
Precise sampling/gas flow:
 Barometry
 Gas chromatography
 Analytical instrument sampling systems
Table 1. Absolute Maximum Ratings1
Parameter
Supply voltage (Vsupply)
ESD susceptibility (human body model)
Storage temperature
Soldering time and temperature:
Lead solder temperature (SIP, DIP)
Peak reflow temperature (SMT)
Min.
-12.0
3
-40 [-40]
Max.
12.0
85 [185]
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Unit
Vdc
kV
C [ F]
2