English
Language : 

HT45F5N Datasheet, PDF (183/202 Pages) Holtek Semiconductor Inc – Power Bank ASSP Flash MCU
HT45F5N/HT45FH5N
Power Bank ASSP Flash MCU
CALL addr
Description
Operation
Affected flag(s)
CLR [m]
Description
Operation
Affected flag(s)
CLR [m].i
Description
Operation
Affected flag(s)
CLR WDT
Description
Operation
Affected flag(s)
CPL [m]
Description
Operation
Affected flag(s)
CPLA [m]
Description
Operation
Affected flag(s)
DAA [m]
Description
Operation
Affected flag(s)
Subroutine call
Unconditionally calls a subroutine at the specified address. The Program Counter then
increments by 1 to obtain the address of the next instruction which is then pushed onto the
stack. The specified address is then loaded and the program continues execution from this
new address. As this instruction requires an additional operation, it is a two cycle instruction.
Stack ← Program Counter + 1
Program Counter ← addr
None
Clear Data Memory
Each bit of the specified Data Memory is cleared to 0.
[m] ← 00H
None
Clear bit of Data Memory
Bit i of the specified Data Memory is cleared to 0.
[m].i ← 0
None
Clear Watchdog Timer
The TO, PDF flags and the WDT are all cleared.
WDT cleared
TO ← 0
PDF ← 0
TO, PDF
Complement Data Memory
Each bit of the specified Data Memory is logically complemented (1′s complement). Bits which
previously contained a 1 are changed to 0 and vice versa.
[m] ← [m]
Z
Complement Data Memory with result in ACC
Each bit of the specified Data Memory is logically complemented (1′s complement). Bits which
previously contained a 1 are changed to 0 and vice versa. The complemented result is stored in
the Accumulator and the contents of the Data Memory remain unchanged.
ACC ← [m]
Z
Decimal-Adjust ACC for addition with result in Data Memory
Convert the contents of the Accumulator value to a BCD (Binary Coded Decimal) value
resulting from the previous addition of two BCD variables. If the low nibble is greater than 9
or if AC flag is set, then a value of 6 will be added to the low nibble. Otherwise the low nibble
remains unchanged. If the high nibble is greater than 9 or if the C flag is set, then a value of 6
will be added to the high nibble. Essentially, the decimal conversion is performed by adding
00H, 06H, 60H or 66H depending on the Accumulator and flag conditions. Only the C flag
may be affected by this instruction which indicates that if the original BCD sum is greater than
100, it allows multiple precision decimal addition.
[m] ← ACC + 00H or
[m] ← ACC + 06H or
[m] ← ACC + 60H or
[m] ← ACC + 66H
C
Rev. 1.00
183