HMC696LP4E Datasheet, PDF (2/10 Pages) Hittite Microwave Corporation – SiGe WIDEBAND DIRECT QUADRATURE MODULATOR, 20 - 2700 MHz
v00.0508
HMC696LP4E
SiGe WIDEBAND DIRECT QUADRATURE
MODULATOR, 20 - 2700 MHz
Electrical Specifications, (continued)
Parameter
RF Output
RF Frequency Range
RF Return Loss
LO Input
LO Frequency Range
LO Input Power
LO Port Return Loss
Baseband Input Port
Baseband Input DC Voltage (Vbbdc)
Baseband Input DC Bias Current (Ibbdc)
Single-ended Baseband Input Capacitance
DC Power Requirements
Supply Voltage (Vcc1, Vcc2)
Supply Current (Icc1 + Icc2)
Conditions
Single-ended.
De-embed to the lead of the device.
See Test Conditions Below
Min.
Typ.
Max. Units
20
2700
MHz
27
dB
20
2700
MHz
0
10
dBm
10
dB
1.5
1.7
V
60
μA
4.5
pF
4.5
5
5.5
V
140
160
180
mA
Test Conditions: Unless Otherwise Specified, the Following Test Conditions Were Used
Parameter
Condition
Temperature
+25 °C
Baseband Input Frequency
200 kHz
Baseband Input DC Voltage (Vbbdc)
+1.5V
Baseband Input AC Voltage
(Peak to Peak Differential, I and Q)
700 mV
Baseband Input AC Voltage for OIP3 Measurement (Peak to Peak Differential, I and Q)
700 mV per tone @ 150 & 250 kHz
Frequency Offset for Output Noise Measurements
30 MHz
Supply (Vcc1, Vcc2)
+5V
LO Input Power
0 dBm
LO Input Mode
Single-Ended through LOP
Mounting Configuration
Refer to HMC696LP4E Application Schematic Herein
Sideband & Carrier Feedthrough
Uncalibrated
10
Calibrated vs. Uncalibrated Test Results
During the Uncalibrated Sideband and Carrier Suppression tests, care is taken to ensure that the I/Q signal paths from
the Vector Signal Generator (VSG) to the Device Under Test (DUT) are equal. The “Uncalibrated, +25 °C” Sideband
and Carrier Suppression plots were measured at room temperature, while the “Uncalibrated, over Temperature”
Sideband and Carrier Suppression plots represent the worst case uncalibrated suppression levels measured at T=
-40 °C, +25 °C, and +85 °C.
The “Calibrated, + 25 °C” Sideband Suppression data was plotted after a manual adjustment of the I/Q amplitude
balance and I/Q phase offset (skew) at +25 °C, and at each LO input power level. The +25 °C adjustment settings
were held constant during tests over temperature. The “Calibrated, over Temperature” plots represent the worst case
calibrated Sideband Suppression levels at T= -40 °C, +25 °C, and +85 °C.
The “Calibrated, +25 °C” Carrier Suppression data was plotted after a manual adjustment of the Ip/In & Qp/Qn DC
offsets at +25 °C, and at each LO input power level. The +25 °C adjustment settings were held constant during tests
over temperature. The “Calibrated, over Temperature” plots represent the worst case Carrier Suppression levels
measured at T= -40 °C, +25 °C, and +85 °C.