English
Language : 

HMC600LP4_09 Datasheet, PDF (2/8 Pages) Hittite Microwave Corporation – 75 dB LOGARITHMIC DETECTOR / CONTROLLER 50 - 4000 MHz
HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Electrical Specifications, (continued)
Parameter
Current Drive (Sink)
Output Voltage Range
Small Signal Response Time (10% to 90%)
Large Signal Response Time
(±0.5 dB Settling)
Output Rise Time
Ripple
VSET Interface
Input Impedance
Input Voltage Range
Low Frequency Gain
Open Loop Corner Frequency
Power Down (PWD) Interface
Voltage Range for Normal Mode
Voltage Range for Shutdown Mode
Threshold Voltage
Power-up Response Time
Power-Down Response Time
Power Supply (Vcc1, Vcc2)
Operating Voltage Range
Supply Current in Normal Mode
Supply Current in Power Down Mode
Conditions
For 1% change in the output voltage
Pin = -60 to -57 dBm
Pin = No Signal to 0 dBm
From 0% to 90%
Fin = 100 MHz
VSET to LOGOUT
50% PWD to ±0.5 dB Settling of LOGOUT
50% PWD to 10% Icc
Vcc = +3.3V, PWD = 0V
Vcc = +3.3V, PWD = Vcc
Test Conditions
Parameter
Condition
Vcc1, Vcc2
+3.3V
Input Zo
50Ω
TA
+25C
Fin
900 MHz
INN Port connected to ground through a 1000pF capacitor
Min.
Typ.
Max.
Units
2.25
mA
0
Vcc -0.13
V
50
ns
150
ns
90
ns
<2
mVpp
30
kΩ
0.6 to 1.9
V
78
dB
1.6
kHz
0
0.2 x Vcc
V
0.8 x Vcc
Vcc
V
Vcc/2
V
1
μs
2.5
μs
2.7
5.5
V
29
36
mA
1
mA
LOGOUT Voltage & Error
vs. Input Power, Fin = 50 MHz
2
5
Ideal
1.6
LOGOUT +25 C
LOGOUT +85 C
3
LOGOUT -40 C
1.2
1
0.8
-1
ERR +25 C
0.4
ERR +85 C
ERR -40 C
-3
0
-5
-75 -65 -55 -45 -35 -25 -15 -5
5
INPUT POWER (dBm)
LOGOUT Voltage & Error
vs. Input Power, Fin = 100 MHz
2
5
Ideal
1.6
LOGOUT +25 C
LOGOUT +85 C
3
LOGOUT -40 C
1.2
1
0.8
-1
0.4
ERR +25 C
-3
ERR +85 C
ERR -40 C
0
-5
-75 -65 -55 -45 -35 -25 -15 -5
5
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12
12 - 3