English
Language : 

DF60 Datasheet, PDF (9/12 Pages) Hirose Electric – 65A 10.16mm pitch Wire-to-Board Connectors for Internal Power Supply
DF60 Series●65A 10.16mm pitch Wire-to-Board Connectors for Internal Power Supply(UL, C-UL, TÜV certified product)
BRemoving Contacts
●Contact extraction tool: precision screwdriver (flathead screwdriver with 1.4mm in width across flats)
●For Crimp contacts: DF60-8SC(F)A, DF60-1012SC(F)A, DF60-8PC(F)A, DF60-1012PC(F)A
●Procedure
ɹSectioned drawing of the housing
BdaYZYaVcXZ
1SFDJTJPO
TDSFXESJWFS
1. After unmating the parts,
position the screwdriver to
raise the lance as shown in
the illustration.
#FGPSFBUUFNQUJOHUPSFNPWFBOZDPOUBDUT 
NBLFTVSFUIBUUIFQPXFSJTTXJUDIFEP⒎BOEUIFTZTUFNJTEFFOFSHJ[FE
2. T h e l a n c e n e e d s t o b e
raised sufficiently to allow the
terminated wire to slip past it.
The lance needs to be held
up while at the same time
pulling on the wire.
Due to any previous repairs, the strength of the lance could have been compromised. Hirose recommends the
use of a new crimp housing to assure proper performance.
Caution
Please be very careful when removing the contact
work so that you don’t become injured by the
protruding part of the crimp contact.
BPrecautions for use
1. The connector could be damaged if it is pulled out forcibly. When it is hard to pull out, push it in slightly first and then depress
the lock and un- mate.
2. When thick, short sections of wire are used, the connector could be deformed due to the force of the wires’ position. Route
cables in such a way that they do not twist when being installed.
3. Make sure to turn off the power when mating or un-mating the connector.
4. Please do not touch any area around the contact part with your hand when the power is on; it could be very dangerous.
5. Please contact our Sales Department about the assembly procedure and the instruction manual.
BRated values
Please avoid using the device above the rated values. Also, do not insert or pull out energized or “ live” wires.
BOperating environment
Please contact us if you are designing this connector into environmental conditions where high and low temperatures
are repeated.
9