English
Language : 

S10140-1007_15 Datasheet, PDF (6/13 Pages) Hamamatsu Corporation – CCD area image sensor
CCD area image sensor
S10140/S10141 series
Timing chart
Line binning
Integration period
(shutter must be open)
Tpwv
1
P1V
Vertical binning period
(shutter must be closed)
3..126 127
3..254 255
3..510 511
2
Readout period (shutter must be closed)
128← 122 + 6 (bevel): S1014*-1007/-1107
256← 250 + 6 (bevel): S1014*-1008/-1108
512← 506 + 6 (bevel): S1014*-1009/-1109
Tovr
P2V, TG
P1H
Tpwh, Tpws
1
2
4..1042 1043
4..2066 2067
3
1044: S1014*-1007/-1008/-1009
2068: S1014*-1107/-1108/-1109
P2H, SG
RG
OS
Tpwr
D1
D2 S1..S1024
D19
D20 : S1014*-1007/-1008/-1009
D3..D10, S1..S2048, D11..D18
: S1014*-1107/-1108/-1109
KMPDC0242EB
Parameter
Symbol
Min.
S1014*-1007
1.5
P1V, P2V, TG*16
Pulse width
S1014*-1008/-1107
S1014*-1009/-1108
Tpwv
3
6
S1014*-1109
12
Rise and fall times
Tprv, Tpfv
20
P1H, P2H*16
Pulse width
Rise and fall times
Tpwh
Tprh, Tpfh
1000
10
Duty ratio
-
40
Pulse width
Tpws
1000
SG
Rise and fall times
Tprs, Tpfs
10
Duty ratio
-
40
RG
Pulse width
Rise and fall times
Tpwr
100
Tprr, Tpfr
5
TG – P1H
Overlap time
Tovr
1
*16: Symmetrical clock pulses should be overlapped at 50% of maximum pulse amplitude.
Typ.
2
4
8
16
-
2000
-
50
2000
-
50
1000
-
2
Max.
Unit
-
-
-
μs
-
-
ns
-
ns
-
ns
60
%
-
ns
-
ns
60
%
-
ns
-
ns
-
μs
6