Calculation method of frame rate
Frame rate=1/(Time per frame)
=1/(Integration time + Readout time)
Integration time:
It is necessary to be changed by the required distance accuracy and usage environment factors such as ï¬uctuating background light.
Readout time=
1
à Horizontal timing clock à Number of vertical pixels
Clock pulse frequency
=Time per clock (Readout time per pixel) à Horizontal timing clocks à Number of vertical pixels
Calculation example of readout time (clock pulse frequency: 5 MHz, horizontal timing clocks: 110, number of vertical pixels: 72)
Readout time=
1
à 110 à 72
5Ã 106 [Hz]
=200 [ns] Ã 110 Ã 72
=1.584 [ms]