English
Language : 

S11105_15 Datasheet, PDF (5/9 Pages) Hamamatsu Corporation – CMOS linear image sensors
CMOS linear image sensors
S11105 series
Timing chart
CLK
ST
Video
Trig
EOS
Integration time
thp(ST)
512
tf(CLK)
123
17 18 19
46 47 48 49 50 51
tpi(ST)
tlp(ST)
1
512
tr(CLK)
CLK
1/f(CLK)
ST
tr(ST)
tf(ST)
thp(ST)
tpi(ST)
tlp(ST)
KMPDC0322EC
Parameter
Symbol
Min.
Typ.
Max.
Unit
Start pulse width interval
Start pulse high period*11
tpi(ST)
58/f(CLK)
-
thp(ST)
6/f(CLK)
-
100 m
s
-
s
Start pulse low period
tlp(ST)
52/f(CLK)
-
-
s
Start pulse rise and fall times
tr(ST), tf(ST)
0
5
7
ns
Clock pulse duty
-
45
50
55
%
Clock pulse rise and fall times
tr(CLK), tf(CLK)
0
5
7
ns
*11: The integration time equals the high period of ST.
The shift register starts operation at the rising edge of CLK immediately after ST goes low.
The integration time can be changed by changing the ratio of the high and low periods of ST.
If the first Trig pulse after ST goes low is counted as the first pulse, the Video signal of the first channel is acquired at the falling
edge of the 49th Trig pulse.
5