English
Language : 

G11097-0606S_15 Datasheet, PDF (5/9 Pages) Hamamatsu Corporation – Image sensor with 64 x 64 pixels developed for two-dimensional infrared imaging
InGaAs area image sensor
G11097-0606S
Timing chart
The video output from a single pixel is equal to 8 MCLK (master clock) pulses. The MSP (master start pulse) is a signal for setting the
integration time, so making the low (0 V) period of the MSP longer will extend the integration time. The MSP also functions as a signal
that triggers each control signal to perform frame scan. When the MSP goes from low (0 V) to high (5 V) , each control signal starts on
the falling edge of the MCLK and frame scan is performed during the high period of the MSP.
One frame scanning period [64 rows × 64 columns (including blank) × 8 MCLK]
MCLK
(input)
MSP
(input)
AD_TRIG
(output)
VIDEO
(output)
(Video űŦųŪŰť)
(Integration time)*1 90 MCLK 8 MCLK
(Blank period) (1 ch)
8 MCLK 94 MCLK*2 8 MCLK
(2 ch) (Blank period) (65 ch)
8 MCLK
(66 ch)
tf(MCLK)
tr(MCLK) tpw(MCLK)
8 MCLK 6 MCLK (Reset period)*3
(4096 ch) (Blank period)
t2
t1
t3
tf(MSP)
tr(MSP)
tpw(MSP)
Integration time
*1: A minimum number of MCLK of integration time is 40 MCLK.
*2: There are blanks of 94 MCLK between each row.
*3: A minimum number of MCLK of reset period is 200 MCLK.
KMIRC0044EC
KMIRC0044EC
Parameter
Clock pulse rise/fall times
Symbol
Min.
tr(MCLK)
0
tf(MCLK)
Typ.
10
Max.
Unit
12
ns
Clock pulse width
Start pulse rise/fall times
Start pulse width*3
Start (rise) timing*4
Start (fall) timing*4
Output setting time
tpw(MCLK)
10
-
tr(MSP)
0
10
tf(MSP)
tpw(MSP)
0.001
-
t1
10
-
t2
10
-
t3
-
-
-
ns
12
ns
10
ms
-
ns
-
ns
50
ns
*3: Integration time max.=10 ms
*4: If the sensor is driven with these timings set shorter than the Min. value, then the operation may delay by 1 MCLK pulse.