S10077_15 Datasheet, PDF (4/8 Pages) Hamamatsu Corporation – CMOS linear image sensor | |||
|
◁ |
CMOS linear image sensor
Timing Chart
tf(CLK)
CLK
tr(CLK)
S10077
ST
tf(ST)
tlp(ST)
tr(ST)
tpi(ST)
thp(ST)
KMPDC0224EB
Parameter
Symbol
Min.
Typ.
Max.
Unit
Start pulse interval
tpi(ST)
12339/f(CLK)
-
120000/f(CLK)
s
Start pulse low period
tlp(ST)
45/f(CLK)
-
-
s
Start pulse high period*13
thp(ST)
6000/f(CLK)
-
-
s
Start pulse rise and fall times
tr(ST), tf(ST)
0
20
30
ns
Clock pulse duty
-
40
50
60
%
Clock pulse rise and fall times
tr(CLK), tf(CLK)
0
20
30
ns
*13: Signal charge integration time equals the high period of start pulse + 7 CLK cycles.
The shift register operation starts at the fall of CLK pulse immediately after ST pulse sets to low.
Integration time can be changed by changing the high-to-low ratio of ST pulses.
4
|
▷ |