English
Language : 

S12571-010_15 Datasheet, PDF (3/6 Pages) Hamamatsu Corporation – Low afterpulses, wide dynamic range, for high-speed measurement Photosensitive area: 1 x 1 mm
MPPC (multi-pixel photon counter)
S12571-010, -015C/P
Photon detection efficiency vs. wavelength
S12571-010C/P
(Typ.=25 °C, Vop=VBR + 4.5 V)
50
S12571-015C/P
(Typ.=25 °C, Vop=VBR + 4.0 V)
50
40
40
S12571-015P
30
30
20
S12571-010P
10
0
300
S12571-010C
400 500 600 700
Wavelength (nm)
800 900
KAPDB0215EA
Photon detection efficiency does not include crosstalk or afterpulses.
20
S12571-015C
10
0
300 400 500 600 700 800 900
Wavelength (nm)
KAPDB0216EA
Gain vs. overvoltage
5 × 105
(Typ. Ta=25 °C)
4 × 105
S12571-015C
3 × 105
2 × 105
1 × 105
S12571-010C
0
0123456789
Overvoltage (V)
KAPDB0244EA
Photon detection efficiency vs. overvoltage
(Typ. Ta=25 °C, λ=408 nm)
60
50
S12571-015C
40
30
20
10
S12571-010C
0
012345678
Overvoltage (V)
KAPDB0245EB