English
Language : 

GS81314LD37GK-800 Datasheet, PDF (27/39 Pages) GSI Technology – Burst of 4 Single-Bank ECCRAM
GS81314LD19/37GK-933/800
Operating Currents
Parameter
x18 Operating Current
x36 Operating Current
Notes:
1. IOUT = 0 mA; VIN = VIH or VIL.
2. Applies at 100% alternating Reads and Writes.
Symbol
IDD
IDD
VDD (nom)
1.3V
1.2V
1.3V
1.2V
AC Test Conditions
Parameter
Core Supply Voltage (-933 speed grade)
Core Supply Voltage (-800 speed grade)
I/O Supply Voltage
Input Reference Voltage
Input High Level
Input Low Level
Input Rise and Fall Time
Input and Output Reference Level
Note: Output Load Conditions RQ = 200. Refer to figure below.
Symbol
VDD
VDD
VDDQ
VREF
VIH
VIL
—
—
AC Test Output Load
800 MHz
2050
1800
2700
2450
933 MHz
2250
—
2950
—
Conditions
1.25 to 1.35
1.15 to 1.35
1.15 to 1.25
0.6
0.9
0.3
2.0
0.6
Output
50
50
VDDQ/2
5 pF
Units
mA
mA
mA
mA
Units
V
V
V
V
V
V
V/ns
V
Rev: 1.02 3/2016
27/39
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.
© 2015, GSI Technology