English
Language : 

050_304 Datasheet, PDF (2/8 Pages) Glenair, Inc. – MIL-DTL-38999 type receptacle connector
050-304
D38999 Series III Type Active Receptacle Connector
with Glenair Size 8 Opto-electronic Contacts
How To Order
Shell Size/Insert
Arrangement
J8 - 25-08 (MIL-STD-1560)
H6 - 23-06 (Glenair pattern)
G4 - 21-75 (MIL-STD-1560)
F4 - 19C-04 (Glenair pattern)
E2 - 17C-75 (Glenair pattern)
B1 - 11L-01 (Glenair pattern)
Product
Series
Finish
(Table I)
Contact Type
(See Table II)
PCB Standoff
Option
01 - Standard
050 - 304 NF - 07 J8 T - A1 - 01 N
D38999 Series III
Active Receptacle
Shell Mounting Options
CS - Wall Mount, Clinch Nut Standard
(38999/20 Modified)
00 - Wall Mount, Slotted (38999/20)
07 - Jam Nut Mount
Opto-Electronic Function
(See Table IX)
T = Transmitter
R = Receiver
X = Transceiver
38999 Polarization
A, B, C, D, E
N = Normal
Notes
• This connector is designed to meet applicable dimensional, environmental and
performance characteristics of D38999 Series III per appropriate material class
• For opto-electric performance specifications, see Table II
• This connector mates with standard MIL-DTL-38999/26 plug connector. See Table X for
applicable part numbers
• For cleaning tools and instructions, see GCLT-H125 in Glenair Fiber Optic catalog
• Receptacle contact removal tool: M81969/14-12
Plug contact insertion/removal tool: M81969/14-03
© 2013 Glenair, Inc.
Rev. 01.19.15
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
30
E-Mail: sales@glenair.com