English
Language : 

050_315 Datasheet, PDF (10/15 Pages) Glenair, Inc. – PRODUCT BRIEF
050-315 Product Brief
PCB Mount Transceiver
100 Mbps – 5 Gbps, MMF, 3.3V
FIGURE 4 RECOMMENDED HOST BOARD POWER SUPPLY FILTERING CIRCUIT
Fiber Compatibility
The transceiver is capable of transmission at 2 to 550 meters with 50/125 μm fiber, and at 2 to 275 meters with 62.5 125
μm fiber, for 1.25 GBd Ethernet. It is capable of transmission up to 550m with 50/125 μm fiber and up to 300m with
62.5/125 μm fiber, for 1.0625 GBd Fiber Channel.
Electrostatic Discharge (ESD)
The Transceiver is compatible with ESD levels found in typical manufacturing and operating environments as described
JEDEC EIA JESD22-A114, Class 1C (<2000Volts) HBM. Glenair recommends that devices are handled with ESD
precautions to limit exposure to below 500V HBM.
There are two design cases in which immunity to ESD damage is important. The first case is during handling of the
transceiver prior to insertion to the host board. To protect the transceiver, it’s important to use standard industry ESD
handling precautions. These precautions include using grounded wrist straps, work benches, and floor mats in ESD
controlled areas. The ESD sensitivity of the Glenair PCB Mount Transceiver is compatible with typical industry production
environments.
The second case to consider is static discharges to the exterior of the host equipment after installation, in which case the
transceiver may be subject to system-level ESD requirements.
©2014 Glenair, Inc.
GLENAIR, INC.
www.glenair.com
REV: C
∙ 1211 AIR WAY
US Cage Code 06324
∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000
PAGE 10 of 15
Printed in USA
∙ FAX: 818-500-9912
E-mail: sales@glenair.com