Table 4-10: Supported Video Standard Codes (Continued)
SMPTE Active Video Area
Standard
RATE_
DET[1]
HD/3G
RATE_
DET[0]
SD/HD
Lines
per
Frame
Active
Lines per
Frame
Words
per
Active
Line
Words VD_STD
per Line
[5:0]
Unknown
HD
Unknown
SD
Unknown
3G
SD/HD = 0
SD/HD = 1
SD/HD = 0
0
0
−
−
−
−
1Dh
x
1
−
−
−
−
1Eh
1
0
−
−
−
−
3Ch
2K Standards (see 4.13.1 2K Support)
2048-2-
2048x1080/30 (1:1)
0
200xX
(4:2:2)
2048x1080/25 (1:1)
0
2048x1080/24 (1:1)
0
0
1125
1080
2048
2200
31h
0
1125
1080
2048
2640
32h
0
1125
1080
2048
2750
33h
2048x1080/60 (1:1)
1
0
1125
1080
2048
2200
37h
2048x1080/50 (1:1)
1
0
1125
1080
2048
2640
38h
2048x1080/48 (1:1)
1
0
1125
1080
2048
2750
39h
2048-2-
2048x1080/30 (1:1)
1
200X
(4:4:4)
2048x1080/25 (1:1)
1
2048x1080/24 (1:1)
1
0
1125
1080
2048
2200
34h
0
1125
1080
2048
2640
35h
0
1125
1080
2048
2750
36h
Non
SMPTE or
2048-2-
200xX
(4:2:2)
Level B
DS1 and
DS2
2048x1080/60 (2:1)
2048x1080/50 (2:1)
2048x1080/48 (2:1)
0 (1)
0 (1)
0 (1)
0
1125
540
2048
2200
3Dh
0
1125
540
2048
2640
3Eh
0
1125
540
2048
2750
3Fh
Non
Unknown 2K
x
SMPTE
0
−
−
2048
−
3Ah
NOTES:
1. The Line Numbers in brackets refer to version zero SMPTE 352M packet locations, if they are different from version 1.
2. The part may provide full or limited functionality with standards that are not included in this table. Please consult a Semtech
technical representative.
3. For SD-SDI streams, the device can report an incorrect M value when SMPTE-352M packets are present.
NOTE: In certain systems, due to greater ppm offsets in the crystal, the ‘M’ bit may not
assert properly. In such cases, bits 3:0 in Register 06Fh can be increased to a maximum
value of 4.
By default (after power up or after systems reset), the four RASTER_STRUCTURE,
VD_STD, STD_LOCK and INT/PROG registers are set to zero. These registers are also
cleared when the SMPTE_BYPASS pin is LOW.