English
Language : 

GS9035C Datasheet, PDF (4/14 Pages) Gennum Corporation – GENLINX II -TM GS9035C Serial Digital Reclocker
PIN CONNECTIONS
Fig. 1 Jitter Measurement Test Setup
4 3 2 1 28 27 26
DDI 5
25 SDO
DDI 6
24 SDO
VEE 7
VEE 8
VCC1 9
AUTO/MAN 10
GS9035C
TOP VIEW
23 SCO
22 SCO
21 SSO
20 SS1
VEE 11
19 RSV1
12 13 14 15 16 17 18
PIN DESCRIPTIONS
NUMBER SYMBOL
1,7,8,11,27
2
VEE
COSC
3
LOCK
4
5, 6
9
10
12
13
14
15
16
17
18
19
20 - 21
SMPTE
DDI/DDI
VCC1
AUTO/MAN
LF+
LFS
LF-
RVCO_RTN
RVCO
CBG
VCC2
RSV1
SS[1:0]
22, 23
SCO/SCO
24, 25
SDO/SDO
26
VCC3
28
CLK_EN
TYPE
DESCRIPTION
I Most negative power supply connection.
I Timing control capacitor for internal system clock.
O Lock indication. When HIGH, the GS9035C is locked. LOCK is an open collector output and
requires an external 10k pullup resistor.
I SMPTE/Other rate select.
I Digital data input (Differential ECL/PECL).
I Most positive power supply connection.
I Auto or Manual mode select. TTL/CMOS compatible input.
I Loop filter component connection.
I Loop filter component connection.
I Loop filter component connection.
I RVCO return.
I Frequency setting resistor.
I Internal bandgap voltage filter capacitor.
I Most positive power supply connection.
I Reserved Input. Always connect to GND
I/O Data rate indication (Auto mode) or data rate select (Manual mode). TTL/CMOS compatible I/O. In
auto mode these pins can be left unconnected.
O Serial clock output. SCO/SCO are differential current mode outputs and require external 75Ω
pullup resistors.
O Serial data output. SDO/SDO are differential current mode outputs and require external 75Ω pullup
resistors.
I Most positive power supply connection.
I Clock enable. When HIGH, the serial clock outputs are enabled.
GENNUM CORPORATION
4 of 14
20582 - 3