APXS002A0X-SRZ Datasheet, PDF (2/24 Pages) General Semiconductor – 2A PicoTLynxTM: Non-Isolated DC-DC Power Modules 3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
GE
2A PicoTLynxTM: Non-Isolated DC-DC Power Modules
3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current
Data Sheet
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
15
Vdc
All
TA
-40
85
°C
All
Tstg
-55
125
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(VIN=3V to 14V, IO=IO, max )
Input No Load Current
(VIN = 12.0Vdc, IO = 0, module enabled)
Input Stand-by Current
(VIN = 12.0Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN = 0 to
14V, IO= IOmax ; See Test Configurations)
Input Ripple Rejection (120Hz)
Device
Symbol
Min
Typ
Max
Unit
All
VIN
3.0
⎯
14.0
Vdc
All
IIN,max
1.8A
Adc
VO,set = 0.6 Vdc
VO,set = 5.5Vdc
All
All
IIN,No load
IIN,No load
IIN,stand-by
I2t
20
mA
48
mA
8
mA
1
A2s
All
20
mAp-p
All
-65
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 4A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further
information.
February 26, 2013
©2013 General Electric Company. All rights reserved.