English
Language : 

GPH5V0-40 Datasheet, PDF (3/8 Pages) Galaxy Power, Inc. – HERCULES Series
Specifications
Output Characteristics
Over the complete baseplate temperatures and input voltage ranges.
Parameter
Name
Test Condition
Var Symbol
Requirement
Unit
Min Typ Max
Output Voltage (nominal)
1.5V
2.2V
3.3V
5.0V
Rated Output Current
1.5V
2.2V
3.3V
5.0V
Initial Output Voltage
Tolerance (with remote sense)
Noise and Ripple
Static Load and
Line Regulation
VOnom
VOnom
VOnom
VOnom
IO
IO
IO
IO
– 1.5
– 2.2
– 3.3
– 5.0
VO = VOnom
0–
VO = VOnom
0–
VO = VOnom
0–
VO = VOnom
0–
Vadj = open, TC = +25°C
-1.25 –
VI = VInom, IO = IOrated/2
20MHzP-P bandwidth,
VI=36-72V, IO = 0 amps to 100%
VI=36-72V, IO = 0.2 amps to 100% – –
–
–
–
–
60/40
Vnom
Vnom
Vnom
Vnom
A
60/40 A
50/40 A
40/30 A
1.25 %VOnom
75 mVP-P
±0.25 %VOnom
Long Term Temperature Drift
-0.5 _ 0.5 %V
Voltage Programming
1.5V
Slope
2.2V
VIN = 48V
VO = VOnom
IO = IOrated/2
Vadj = 0.5V
to 1.5V
– 0.30 – mV/mV
± 0.014
– 0.44 – mV/mV
± 0.02
3.3V
– 0.66 – mV/mV
± 0.03
5.0V
– 1.0 – mV/mV
± 0.04
Vadj Initial Tolerance
Resistance Programming
Tolerance
Total Remote Sense
1.5V
Compensation (round trip) 2.2V
Vadj = 1.0V
Radj = 500Ω
Radj = 1500Ω
VI = VImin, IO = IOmax rated
-11.7
+8.3
–
±1.25 %VOnom
-8.3 %VOnom
+11.7 %VOnom
100 mV
3.3V
–
500 mV
5V
Output Overvoltage Protection
(Latching)
110
127 %VO
prog.
Output Voltage Protection
Response Time
TOVP
VO = VOnom, IO = IOrated
–
30 µs
Note: Overvoltage Protection must function over full programming range. Also, reference for OVP Threshold must be a redundant or equivalent reference.
Hercules Series, Page 3
WWW.GALAXYPWR.COM
Part No. 98–002 Rev. 1.1