Specifications
General Specifications
Operating Temperature -20°C to +100°C baseplate
Storage Temperature
–40°C to +100°C
Relative Humidity
10% to 95% RH,
Non–condensing
Vibration
10–500Hz 0.75g peak
Weight
130gm, maximum
Material Flammability
UL94V–2
Safety UL 1950, CSA C22.2 No. 950 approved1
MTBF MIL–HDBK–217
500,000 hours2
Notes: 1. Requires one fuse located in either the plus or minus side of the 48V
supply; fuse rated for 7A max for all conditions.
2. 80% load; 70°C baseplate.
Input Characteristics
Baseplate Temperatures from 0°C to +100°C.
Parameter
Name
Var
Input Voltage
Input Low Line Power On V
Input Low Line Power Off V
No Load Input Power
Input Capacitor
(external to the converter)
Input Current
1.5V
2.2V
3.3V
5.0V
Inrush Transient
Efficiency
1.5V
2.2V
3.3V
5.0V
Reflected Input Ripple
Maximum Losses at
1.5V
Local Sense
2.2V
3.3V
5.0V
Symbol
VI
VIon
VIoff
PIL
II
II
II
II
Pd
Test Condition
Module Power On
Module Shutdown
VI=VInom
rated 80V min
VI = 36V, IO = 60A, VO = 1.5V
VI = 36V, IO = 60A, VO = 2.2V
VI = 36V, IO = 50A, VO = 3.3V
VI = 36V, IO = 40A, VO = 5.0V
VI = 48V, IO = IO max rated
VO = VO nom , IO = IO rated, VI=VInom
VI = 48V, IO = Io max rated, CI = 250µF
VI = 48V, VO = VOnom
IO = IOmax rated, TCase= 70°C
Requirement
Min
Max
36
72
30
35
80
90
–
2.5
250
–
Unit
V
V
%VIon
W
µF
–
4.0 A
–
5.2 A
–
5.6 A
–
6.3 A
–
1.0
A2s
66
–
%
74
–
%
77
–
%
80
–
%
–
2.5 Ap-p
–
44 W
–
44 W
–
42 W
–
42 W
Hercules Series, Page 2
WWW.GALAXYPWR.COM
Part No. 98–002 Rev. 1.1