English
Language : 

MB39A119 Datasheet, PDF (7/53 Pages) Fujitsu Component Limited. – DC/DC Converter IC of Synchronous Rectification for charging Li-ion battery
MB39A119
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Condition
Value
Unit
Min Typ Max
Power supply voltage
VCC
CB terminal input voltage
VCB
VCC terminal
CB terminal
8
⎯
25
V
⎯
⎯
30
V
Reference voltage output
current
IREF
VREF terminal
−1
⎯
0
mA
Bias output current
IVB
VB terminal
−1
Input voltage
VINE
+ INE1, + INE2, − INE1,
− INE2, − INE3 terminal
0
VINC1 + INC1, −INC1 terminal
7
VINC2 + INC2, −INC2 terminal
0
Input voltage difference
DVINC Current detection voltage range 0
OUTD terminal output voltage VOUTD
OUTD terminal
0
OUTD terminal output current IOUTD
OUTD terminal
0
CTL terminal input voltage
VCTL
CTL terminal
0
ACIN input voltage
VACIN
ACIN terminal
0
ACOK terminal output voltage VACOK
ACOK terminal
0
⎯
0
mA
⎯
5
V
⎯
VCC
V
⎯
19
V
⎯
140 mV
⎯
19
V
⎯
2
mA
⎯
25
V
⎯
VCC
V
⎯
25
V
XACOK terminal output
voltage
VXACOK
XACOK terminal
0
⎯
25
V
CVM terminal output voltage
Peak output current
Oscillation frequency
Timing resistor
Soft-start capacitor
CB terminal capacitor
Bias output capacitor
VCVM
IOUT
fOSC
RT
CS
CB
CVB
CVM terminal
Duty ≤ 5 % (t=1/fOSC × Duty)
⎯
RT terminal
CS terminal
CB terminal
VB terminal
0
⎯
25
V
−1200 ⎯ +1200 mA
200 500 1000 kHz
⎯
39
⎯
kΩ
⎯
0.22
⎯
µF
⎯
0.1
⎯
µF
⎯
1.0
⎯
µF
Reference voltage output
capacitor
CREF
VREF terminal
⎯
0.1
1.0 µF
Operating ambient
temperature
Ta
⎯
−30 +25 +85 °C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
7