MB39A119 Datasheet, PDF (24/53 Pages) Fujitsu Component Limited. – DC/DC Converter IC of Synchronous Rectification for charging Li-ion battery | |||
|
◁ |
MB39A119
â AC ADAPTER DETECTION FUNCTION
When ACIN terminal (pin 4) voltage is lower than 2.0 V (Typ) , AC adapter voltage detection block (AC Comp.)
outputs âHi-Zâ level to the ACOK terminal (pin 5) and outputs âLâ level to the XACOK terminal (pin 22) . When
CTL terminal (pin 21) is set to âLâ level, ACOK terminal (pin 5) and XACOK terminal (pin 22) are fixed to
âHi-Zâ level.
(1) AC adapter presence
The presence of AC adapter can be easily detected because the signal is output from the ACOK terminal (pin
5) to microcomputer etc.
In this case, if CTL terminal (pin 21) is set in âLâ level, IC become the standby state (ICC = 0 µA Typ) .
⢠Connection example of detecting AC adapter presence
AC adapter
Micon
ACIN
4
<AC Comp.>
+
â
ACOK
5
XACOK
22
24
|
▷ |