s RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Conditions
Power supply voltage
Reference voltage output
current
VH terminal output
current
Input voltage
OUTD terminal
output voltage
OUTD terminal
output current
CTL terminal
input voltage
Output current
Peak output current
Oscillation frequency
Timing resistor
Soft-start capacitor
VH terminal capacitor
Reference voltage output
capacitor
Operating ambient
temperature
VCC
IREF
IVH
VINE
VINC
VDTC
VOUTD
IOUTD
VCTL
IOUT
IOUT
fOSC
RT
CS
CVH
CREF
Ta
VCC, VCC (O) terminal


−INE and +INE terminal
−INC and +INC terminal
DTC terminal




Duty ≤ 5 %
(t = 1 / fosc × Duty)






Rating
Unit
Min
Typ
Max
8

25
V
−1

0
mA
0

30
mA
0

VCC − 1.8
V
0

VCC
V
0

VCC − 0.9
V
0

17
V
0

2
mA
0

25
V
−45

+45
mA
−600

+600
mA
100
290
500
kHz
27
43
130
kΩ

0.022
1.0
µF

0.1
1.0
µF

0.1
1.0
µF
−30
+25
+85
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
7