English
Language : 

MB39A113 Datasheet, PDF (6/51 Pages) Fujitsu Component Limited. – ASSP for Power Supply Applications (Secondary Battery)
MB39A113
s ABSOLUTE MAXIMUM RATINGS
Parameter
Power supply voltage
Output current
Peak output current
Power dissipation
Storage temperature
Symbol
Conditions
VCC
IOUT
IOUT
PD
TSTG
VCC terminal

Duty ≤ 5% (t = 1/fosc × Duty)
Ta ≤ +25 °C

Rating
Unit
Min
Max

28
V

60
mA

700
mA

740*
mW
−55
+125
°C
* : The package are mounted on the dual-sided epoxy board (10 cm × 10 cm) .
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING CONDITIONS
Parameter
Power supply voltage
Reference voltage output current
VH terminal output current
Input voltage
CTL terminal input voltage
Output current
Peak output current
CVM terminal output voltage
CVM terminal output current
OVP terminal output voltage
OVP terminal output current
OUTD terminal output voltage
OUTD terminal output current
Oscillation frequency
Timing resistor
Soft-start capacitor
VH terminal capacitor
Reference voltage output capacitor
Operating ambient temperature
Sym-
bol
VCC
IREF
IVH
VINE
VINC
VCTL
IOUT
IOUT
VCVM
ICVM
VOVP
IOVP
VOUTD
IOUTD
fosc
RT
CS
CVH
CREF
Ta
Conditions
Value
Min Typ Max
VCC terminal
8  25

−1  0

0  30
−INE1 to −INE3, + INE1, + INE2 terminal 0  5
+ INC1, + INC2, −INC1, −INC2 terminal 0  VCC

0  25

−45  +45
Duty ≤ 5% (t = 1/fosc × Duty)
−600  +600

0  25

01

0  25

01

0  17

02

100 300 500

27 47 130

 0.022 1.0

 0.1 1.0

 0.1 1.0

−30 +25 +85
Unit
V
mA
mA
V
V
V
mA
mA
V
mA
V
mA
V
mA
kHz
kΩ
µF
µF
µF
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
6