MB3887
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Conditions
Value
Unit
Min
Typ
Max
Power supply voltage
VCC VCC, VCC (O) terminal*
8
Reference voltage output
current
IREF
⎯
−1
VH terminal output current
IVH
⎯
0
Input voltage
VINE
−INE1 to −INE3, +INE1,
+INE2 terminal
0
VINC
+INC1, +INC2, −INC1,
−INC2 terminal
0
⎯
25
V
⎯
0
mA
⎯
30
mA
⎯ VCC − 1.8
V
⎯
VCC
V
OUTD terminal
output voltage
VOUTD
⎯
0
⎯
17
V
OUTD terminal
output current
IOUTD
⎯
0
⎯
2
mA
CTL terminal input voltage
Output current
Peak output current
Oscillation frequency
Timing resistor
Soft-start capacitor
VH terminal capacitor
Reference voltage output
capacitor
VCTL
IOUT
IOUT
fOSC
RT
CS
CVH
CREF
⎯
⎯
Duty ≤ 5 %
(t = 1 / fosc × Duty)
⎯
⎯
⎯
⎯
⎯
0
⎯
25
V
−45
⎯
+45
mA
−600
⎯
+600
mA
100
290
500
kHz
27
47
130
kΩ
⎯
0.022
1.0
µF
⎯
0.1
1.0
µF
⎯
0.1
1.0
µF
Operating ambient
temperature
Ta
⎯
−30
+25
+85
°C
* : For details, refer to “■ THE SEQUENCE OF THE START-UP AND OFF OF THE POWER SUPPLY”.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
6