s USAGE PRECAUTIONS
1. Never use settings exceeding maximum rated conditions.
Exceeding maximum rated conditions may cause permanent damage to the LSI.
Also, it is recommended that recommended operating conditions be observed in normal use.
Exceeding recommended operating conditions may adversely affect LSI reliability.
2. Use this device within recommended operating conditions.
Recommended operating conditions are values within which normal LSI operation is warranted. Standard elec-
trical characteristics are warranted within the range of recommended operating conditions and within the listed
conditions for each parameter.
3. Printed circuit board ground lines should be set up with consideration for common
impedance.
4. Take appropriate static electricity measures.
• Containers for semiconductor materials should have anti-static protection or be made of conductive material.
• After mounting, printed circuit boards should be stored and shipped in conductive bags or containers.
• Work platforms, tools, and instruments should be properly grounded.
• Working personnel should be grounded with resistance of 250 kΩ to 1 MΩ between body and ground.
s ORDERING INFORMATION
Part number
MB3873PF
Package
16-pin plastic SOP
(FPT-16P-M06)
Remarks