English
Language : 

MB39A114 Datasheet, PDF (7/54 Pages) Fuji Electric – DC/DC Converter IC for Charging Li-ion Battery
MB39A114
s RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Conditions
Value
Unit
Min Typ Max
Power supply voltage
VCC VCC terminal
8

25 V
Reference voltage output
current
IREF

−1

0 mA
VH terminal output current
IVH

0

30 mA
Input voltage
VINE −INE1 to −INE3, +INE1, +INE2 terminal 0
VINC +INC1, +INC2, −INC1, −INC2 terminal 0

5
V

VCC
V
CTL terminal input voltage
VCTL

0

25 V
Output current
IOUT

−45  +45 mA
Peak output current
IOUT Duty = 5% (t = 1/fosc × Duty)
−600  +600 mA
CVM terminal output voltage VCVM

0

25 V
CVM terminal output current ICVM

0

1 mA
OVP terminal output voltage VOVP

0

25 V
OVP terminal output current
IOVP

0

1 mA
SEL terminal input voltage
VSEL

0

25 V
Oscillation frequency
fosc

100 300 500 kHz
Timing resistor
RT

27
47 130 kΩ
Soft-start capacitor
CS

 0.022 1.0 µF
VH terminal capacitor
CVH

 0.1 1.0 µF
Reference voltage output
capacitor
CREF

 0.1 1.0 µF
Operating ambient
temperature
Ta

−30 +25 +85 °C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
7