English
Language : 

MB39A114 Datasheet, PDF (32/54 Pages) Fuji Electric – DC/DC Converter IC for Charging Li-ion Battery
MB39A114
s SELECTION OF COMPONENTS
• Pch MOS FET
The P-ch MOS FET for switching use should be rated for at least +20% more than the input voltage. To minimize
continuity loss, use a FET with low RDS(ON) between the drain and source. For high input voltage and high frequency
operation, on-cycle switching loss will be higher so that power dissipation must be considered. In this application,
the NEC µPA2714GR is used. Continuity loss, on/off switching loss and total loss are determined by the following
formulas. The selection must ensure that peak drain current does not exceed rated values.
Continuity loss : Pc
PC
= ID2 × RDS (ON) × Duty
On-cycle swiching loss : PS (ON)
VD (Max) × ID × tr × fosc
PS (ON) =
6
Off-cycle switching loss : PS (OFF)
VD (Max) × ID (Max) × tf × fosc
PS (OFF) =
6
Total loss : PT
PT
= PC + PS (ON) + PS (OFF)
Example : Using the µPA2714GR
16.8 V setting
Input voltage VIN (Max) = 25 V, output voltage VO = 16.8 V, drain current ID = 3 A, oscillation frequency fosc =
300 kHz, L = 15 µH, drain-source on resistance RDS (ON) =: 18 mΩ, tr =: 15 ns, tf =: 42 ns
Drain current (Max) : ID (Max)
ID (Max) = Io +
VIN (Max) − Vo
tON
2L
25 − 16.8
1
= 3+
×
2 × 15 × 10 − 6
300 × 103
=: 3.6 A
× 0.672
Drain current (Min) : ID (Min)
ID (Min) = Io −
VIN (Max) − Vo
tON
2L
= 3−
25 − 16.8
1
×
2 × 15 × 10−6
300 × 103
=: 2.4 A
× 0.672
32