English
Language : 

EDS3-136 Datasheet, PDF (7/16 Pages) Fuji Electric – INFRARED GAS ANALYZER FOR STIC GAS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ZSK
1-
-
-
-
-
A
B
C
D
E
F
G
H
J
K
Contents
Power supply <25th digit>
100V AC 50Hz
100V AC 60Hz
110V AC 50Hz
110V AC 60Hz
115V AC 50Hz
115V AC 60Hz
200V AC 50Hz
200V AC 60Hz
230V AC 50Hz
230V AC 60Hz
Note6)
Application <26th digit>
Note1)
A
Refuse, industrial waste incineration, etc.
B
Gas boiler
C
Sludge incineration
D
Coal-oil boiler
Note1) If 0-500ppm or higher is selected as SO2 first
range for the 9th and 10th digits, or code D is
selected for the 26th digit, select code B, E, or F
with instrumentation air for the 21st digit.
Note2) Only when “Without” is selected for all of the 16
to 19th digits, non-isolated output is allowed.
Combination of isolated and non-isolated outputs
is not allowed.
Note3) Specify this code when the downward inclination
of the sample inlet tube from the gas extraction
point to the analyzer gas inlet is less than 15°C or
when moisture content of the sample gas is
higher than 30%.
Note4) Special specification for cubicle structure
Specified as “Z” at the 20th digit only for cubicle
materials, plate thickness, door with window,
finished color, special coating film.
Note5) The contents to be recorded with a 6-point
recorder are assigned and connected as
specified in the above table for its delivery.
Recorder type: PHR
*Specify separately for other than those in the
following table.
Note6) When 1 to 6 is set for the 24th digit, C to K cannot
be selected for the 25th digit.
Note7) When the measurement method test or the CO2
analyzer is provided, code 3 is specified.
Recording data
Code
12 3 1 2 3
NOx instantaneous value
{
{
average value
{{ {
{
O2 correction value
{
{
SO2 instantaneous value
{
{
average value
{
{
{
O2 correction value
{
CO instantaneous value
{
{
average value
{{
{
O2 correction value
{
O2 instantaneous value
{{{ { { {
Combustion temperature
{{
{
Dust precipitator temperature { {
{
<Specify when placing an order>
(1) Code symbols
(2) Written contents when TAG plate is provided
Y
A
B
C
D
E
F
G
H
J
K
L
M
1
2
3
Y
1
A
B
C
E
G
H
J
K
P
Q
R
D
F
Y
A
B
C
D
E
F
G
H
J
K
L
M
Z
Measuring method test <27th digit>
Without
NOX
SO2
CO
NOX,SO2
NOx,CO
NOX,SO2,CO
NOX,O2
SO2,O2
CO,O2
NOX,SO2,O2
NOx,CO,O2
NOX,SO2,CO,O2
Zero gas <28th digit>
Note7)
Instrumentation air
Atmospheric air
Standard gas ... Separately purchase standard gas
(Type ZSY).
Gas extractor <29th digit>
Extractor Sampling tube Insertion
material
length
Without Without
Without
With
Without
Without
With
SUS316
300mm
With
SUS316
400mm
With
SUS316
600mm
With
SUS316
800mm
With
SUS316
1000mm
With
SUS316
1200mm
With
SUS316
1500mm
With
SUS316
2000mm
With
Titanium
600mm
With
Titanium
800mm
With
Titanium
1000mm
With
SiC
700mm
With
SiC
900mm
Sampling point
temperature
—
—
800°C or lower
800°C or lower
800°C or lower
800°C or lower
800°C or lower
800°C or lower
800°C or lower
800°C or lower
1000°C or lower
1000°C or lower
1000°C or lower
1300°C or lower
1300°C or lower
Sample inlet tube type
Without
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
φ10/φ8mm Teflon tube
Heating tube
Heating tube
Heating tube
Heating tube
Heating tube
Length <30th digit>
Without
5m
10m
15m
20m
25m
30m
50m
10m
15m
20m
25m
30m
Non standard specification <31th digit>
Other specification
7