EDSX6-111E Datasheet, PDF (4/8 Pages) Fuji Electric – ULTRASONIC FLOWMETER < TIME DELTAF (Flexible Type)>
FLH…3, FLW…2, FLD…1
DETECTOR SELECTION
Fluid temperature (°C)
200
High-temperature sensor
(FLD3)
100
80
0
– 40
Small
diameter
sensor
(FLD2)
13
50
Small sensor
(FLW1)
Middle sensor
(FLW4)
Large sensor
(FLW5)
100
200 400
1200
6000 Pipe size (mm)
(Note)
1. High turbid fluid or scales sticking on the internal wall of pipes may interrupt the ultrasonic propagations.
Previous check with a portable type ultrasonic flowmeter is recommended.
2. In case of cast iron pipes or pipes with lining, the Large sensor is recommended rather than the Middle sensor.
3. If the pipe has poor inside surface conditions or highly attenuating fluids, you may not be able to a reliable sig-
nal, therefore you should use the ”FLW50˝ sensor.
SCOPE OF DELIVERY
Flow transmitter (FLH)
Unit name
Scope of delivery
1 Flow
1) Converter
transmitter 2) Parameter table (blank)
3) Manual
Detector (FLW)
Unit name
Scope of delivery
1 Small/high- 1) Sensor unit
tempera-
ture/mid-
dle/large
2) Signal cable (for sub-
merged type)
sensor
3) Mounting chain/wire/
belt
4) Silicone rubber/grease
(100g)
Signal cable (FLY)
Unit name
Scope of delivery
1 Signal cable Special cable (2pcs)
4