English
Language : 

MB91301 Datasheet, PDF (114/135 Pages) Fuji Electric – 32-Bit Proprietary Microcontroller
MB91301 Series
(10) Reload Timer Clock and PPG Timer Input Timings
(VCC = 3.0 V to 3.6 V, VSS = AVSS = 0 V, Ta = 0 °C to +70 °C)
Parameter
Sym-
bol
Pin name
Condition
Value
Min
Max
Unit Remarks
Input pulse width
tTIWH
tTIWL
TIN0 to TIN2,
PPG0 to PPG3,
TRG0 to TRG3
⎯
2 tCYCP*
⎯
ns
* : tCYCP is the peripheral clock cycle time.
TIN0 to TIN2
VIH
PPG0 to PPG3
TRG0 to TRG3
VIH
VIL
VIL
tTIWH
tTIWL
(11) Trigger Input Timing
Parameter
Sym-
bol
A/D activation trigger input time tATGL
(VCC = 3.0 V to 3.6 V, VSS = AVSS = 0 V, Ta = 0 °C to +70 °C)
Value
Pin name Condition
Unit
Min
Max
Remarks
ATG
⎯
5 tCYCP*
⎯
ns
* : tCYCP is the peripheral clock cycle time.
tATGL
ATG
VIL
VIL
114