English
Language : 

FAN4147SX Datasheet, PDF (8/10 Pages) Fairchild Semiconductor – Ground Fault Interrupter
Typical Performance Characteristics
Unless otherwise specified, results are TA=25°C and according to Figure 2 with solenoid disconnected.
Sense amplifier oscillates with 2Ω
grounded neutral fault
Ch1: Line (Pin 3) 10V/Div
Ch2: AmpOut (Pin 6) 5V/Div
Ch3: SCR (Pin 1) 1V/Div
Figure 8. Typical Waveforms for Grounded Neutral Detection
~6.9KHz Sense Amplifier
Oscillation
Ch2: AmpOut (Pin 6) 2V/Div
Figure 9. Typical Waveform for Grounded Neutral Detection
© 2010 Fairchild Semiconductor Corporation
FAN4147 • Rev. 1.0.1
8
www.fairchildsemi.com