English
Language : 

H11F1 Datasheet, PDF (6/9 Pages) Fairchild Semiconductor – PHOTO FET OPTOCOUPLERS
PHOTO FET OPTOCOUPLERS
H11F1 H11F2 H11F3
TYPICAL APPLICATIONS
AS A VARIABLE RESISTOR
ISOLATED VARIABLE ATTENUATORS
AS AN ANALOG SIGNAL SWITCH
ISOLATED SAMPLE AND HOLD CIRCUIT
500K
VIN
IF
VOUT
H11F1
VIN
H11F1
IF
50Ω VOUT
LOW FREQUENCY
@10KHz
DYNAMIC RANGE ≈ 70db
FOR 0 ≤ IF ≤ 30mA
HIGH FREQUENCY
@1MHz
DYNAMIC RANGE ≈ 50db
FOR 0 ≤ IF ≤ 30mA
Distortion free attenuation of low level A.C. signals is accom-
plished by varying the IRED current, IF Note the wide dynamic
range and absence of coupling capacitors; D.C. level shifting or
parasitic feedback to the controlling function.
VIN
H11F1
IF
+
-
C
VIN
VOUT
IF
VOUT
t
Accuracy and range are improved over conventional FET
switches because the H11F has no charge injection from the
control signal. The H11F also provides switching of either
polarity input signal up to 30V magnitude.
AUTOMATIC GAIN CONTROL
MULTIPLEXED, OPTICALLY-ISOLATED A/D CONVERSION
VIN
H11F1
IF
AGC
SIGNAL
+
-
500K
VOUT
CALL V1
H11F1
CALL
Vn
DATA
V1
H74A1
ACQUISITION
V2
MSB
MSB
A/D
PROCESS
CONVERTER
CONTROL
Vn
LSB H74A1
LOGIC
SYSTEM
LSB
H11F1
This simple circuit provides over 70db of stable gain control for
an AGC signal range of from 0 to 30mA. This basic circuit can
be used to provide programmable fade and attack for electronic
music.
The optical isolation, linearity and low offset voltage of the
H11F allows the remote multiplexing of low level analog signals
from such transducers as thermocouplers, Hall effect devices,
strain gauges, etc. to a single A/D converter.
ACTIVE FILTER FINE TUNING/BAND SWITCHING
IF1
IF2
H11F1
H11F1
TEST EQUIPMENT - KELVIN CONTACT POLARITY
H11F1
IF
H11F1
IF
A1
A2
A3
A
ITEST
DEVICE
UNDER
TEST
B
C
PARAMETER
SENSING
BOARD
IF TO
A & B FOR
POLARITY 1
C & D FOR
POLARITY 2
D
IF1 ADJUSTS f1, IF2 ADJUSTS f2
The linearity of resistance and the low offset voltage of the
H11F allows the remote tuning or band-switching of active
filters without switching glitches or distortion. This schematic
illustrates the concept, with current to the H11F1 IRED’s
controlling the filter’s transfer characteristic.
IF
H11F1
IF
H11F1
In many test equipment designs the auto polarity function uses
reed relay contacts to switch the Kelvin Contact polarity. These
reeds are normally one of the highest maintenance cost items
due to sticking contacts and mechanical problems. The totally
solid-State H11F eliminates these troubles while providing
faster switching.
© 2002 Fairchild Semiconductor Corporation