English
Language : 

H11G2SM Datasheet, PDF (4/9 Pages) Fairchild Semiconductor – High Voltage Photodarlington Optocouplers
Safety and Insulation Ratings
As per IEC 60747-5-2, this optocoupler is suitable for “safe electrical insulation” only within the safety limit data.
Compliance with the safety ratings shall be ensured by means of protective circuits.
Symbol
CTI
VPR
VIORM
VIOTM
RIO
Parameter
Installation Classifications per DIN VDE 0110/1.89
Table 1
For Rated Main Voltage < 150Vrms
For Rated Main voltage < 300Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Comparative Tracking Index
Input to Output Test Voltage, Method b,
VIORM x 1.875 = VPR, 100% Production Test
with tm = 1 sec, Partial Discharge < 5pC
Input to Output Test Voltage, Method a,
VIORM x 1.5 = VPR, Type and Sample Test
with tm = 60 sec, Partial Discharge < 5pC
Max. Working Insulation Voltage
Highest Allowable Over Voltage
External Creepage
External Clearance
Insulation Thickness
Insulation Resistance at Ts, VIO = 500V
Min.
175
1594
1275
850
6000
7
7
0.5
109
Typ.
Max.
I-IV
I-IV
55/100/21
2
Unit
Vpeak
Vpeak
Vpeak
Vpeak
mm
mm
mm
Ω
©2007 Fairchild Semiconductor Corporation
H11G1M, H11G2M, H11G3M Rev. 1.0.4
4
www.fairchildsemi.com