AC Electrical Characteristics
Symbol
Parameter
VCC
TA = 25°C
TA = −40°C to +85°C
Units
(V)
Min
Typ
Max
Min
Max
Conditions
fMAX
tPLH
tPHL
tPLH
tPHL
CIN
CPD
Maximum Clock Frequency 3.3 ± 0.3 80
125
50
75
65
MHz CL = 15 pF
45
CL = 50 pF
5.0 ± 0.5 125
175
85
115
105
MHz CL = 15 pF
75
CL = 50 pF
Propagation Delay
Time (CP–Qn)
3.3 ± 0.3
8.4
12.8
1.0
15.0
ns CL = 15 pF
10.9
16.3
1.0
18.5
CL = 50 pF
5.0 ± 0.5
5.8
9.0
1.0
10.5
ns CL = 15 pF
7.3
11.0
1.0
12.5
CL = 50 pF
Propagation Delay
Time (MR–Qn)
3.3 ± 0.3
8.3
12.8
1.0
15.0
ns CL = 15 pF
10.8
16.3
1.0
18.5
CL = 50 pF
5.0 ± 0.5
5.2
8.6
1.0
10.0
ns CL = 15 pF
6.7
10.6
1.0
12.0
CL = 50 pF
Input Capacitance
4
10
10
pF VCC = Open
Power Dissipation
76
pF (Note 4)
Capacitance
Note 4: CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load. Average
operating current can be obtained from the equation: ICC (opr.) = CPD * VCC * fIN + ICC.
AC Operating Requirements
Symbol
Parameter
tW(L)
tW(H)
tW(L)
Minimum Pulse Width (CP)
Minimum Pulse Width (MR)
tS
Minimum Setup Time
tH
Minimum Hold Time
tREC
Minimum Removal Time (MR)
Note 5: VCC is 3.3 ± 0.3V or 5.0 ± 0.5V
VCC
(V)
(Note 5)
3.3
5.0
3.3
5.0
3.3
5.0
3.3
5.0
3.3
5.0
TA = 25°C
TA = −40°C to +85°C
Typ
Guaranteed Minimum
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
6.0
4.5
4.5
0.0
0.0
1.0
1.0
2.5
2.5
2.5
2.5
Units
ns
ns
ns
ns
ns
www.fairchildsemi.com
4