English
Language : 

MA120 Datasheet, PDF (3/5 Pages) Extech Instruments Corporation. – 200A AC/DC Mini Clamp-on Meter
Meter Description
1. Current sense jaw
2. Non-contact AC voltage indicator light
3. Flashlight button
4. Rotary function switch
2
1
3
4
5. Data HOLD and Backlight key
6. LCD display
7. Clamp trigger
8. One-touch DCA ZERO key
5
6
78
Safety Information
!
Caution! Refer to the explanation in this Manual
Double Insulation
This meter has been designed to be safe in use, but the operator must use caution in its
operation. The rules listed below should be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
2. USE EXTREME CAUTION when working with voltages greater than 60VDC or 25VAC
rms. These voltages are considerd a shock hazard.
3. NEVER operate the meter unless the back cover and the battery/fuse door are in place
and fastened securely.
Function
AC Current
DC Current
Frequency
Input Limits
Maximum Input
200A
±200A
1kHz
3
MA120 Ver. 1.2 10/2004