Specifications
General Specifications
Display
Polarity
Current sensor
Overload indication
DCA zero adjust
Display rate
Battery
Low Battery indication
Operating conditions
Storage conditions
Altitude
Weight
Dimensions
Jaw opening
Standards
Range Specifications
3-2/3 (2400 count) Digit LCD with white LED backlight
Minus sign ( - ) indicates negative polarity
Hall effect sensor type
âOLâ displayed on the LCD
One touch zero key
2 readings/second, nominal
Two 1.5V AAA batteries
âBATTâ displayed on the LCD
32ºF to 86ºF (0ºC to 30ºC) 90%RH; 86ºF to 104ºF (30ºC to 40ºC)
75%RH; 104ºF to 122ºF (40ºC to 50ºC) 45%RH
- 14ºF to 140ºF (-30ºC to 60ºC); < 90% Relative Humidity
Operate at less than 3000 meters
6.2 oz. (176g) including battery
6.5 x 2.6 x 1.3â (164 x 65 x 32mm) (HWD)
0.7â (18mm)
CC IEC 1010 Category III 300V, Category II 600V,
Function
Range Resolution
Accuracy (of reading)
DC Current
200A
0.1A
± (2.8% + 8 digits)
AC Current
200A
0.1A
±(3.0% + 8 digits)
Frequency
(Auto-Ranging)
40-51Hz 0.01Hz
51-510Hz 0.1Hz
±(1.2% + 5 digits)
Input Sensitivity: 2.5A AC RMS min.
0.51-1kHz 0.001kHz
Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz
2
MA120 Ver. 1.2 10/2004
|
▷ |