English
Language : 

MA120 Datasheet, PDF (2/5 Pages) Extech Instruments Corporation. – 200A AC/DC Mini Clamp-on Meter
Specifications
General Specifications
Display
Polarity
Current sensor
Overload indication
DCA zero adjust
Display rate
Battery
Low Battery indication
Operating conditions
Storage conditions
Altitude
Weight
Dimensions
Jaw opening
Standards
Range Specifications
3-2/3 (2400 count) Digit LCD with white LED backlight
Minus sign ( - ) indicates negative polarity
Hall effect sensor type
“OL” displayed on the LCD
One touch zero key
2 readings/second, nominal
Two 1.5V AAA batteries
“BATT” displayed on the LCD
32ºF to 86ºF (0ºC to 30ºC) 90%RH; 86ºF to 104ºF (30ºC to 40ºC)
75%RH; 104ºF to 122ºF (40ºC to 50ºC) 45%RH
- 14ºF to 140ºF (-30ºC to 60ºC); < 90% Relative Humidity
Operate at less than 3000 meters
6.2 oz. (176g) including battery
6.5 x 2.6 x 1.3” (164 x 65 x 32mm) (HWD)
0.7” (18mm)
CC IEC 1010 Category III 300V, Category II 600V,
Function
Range Resolution
Accuracy (of reading)
DC Current
200A
0.1A
± (2.8% + 8 digits)
AC Current
200A
0.1A
±(3.0% + 8 digits)
Frequency
(Auto-Ranging)
40-51Hz 0.01Hz
51-510Hz 0.1Hz
±(1.2% + 5 digits)
Input Sensitivity: 2.5A AC RMS min.
0.51-1kHz 0.001kHz
Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz
2
MA120 Ver. 1.2 10/2004