English
Language : 

SP26LV431 Datasheet, PDF (5/22 Pages) Sipex Corporation – High Speed, +3.3V Quad RS-422 Differential Line Driver
SP26LV431
REV. 1.1.0
HIGH SPEED +3.3V QUAD RS-422 DIFFERENTIAL LINE DRIVER
UNLESS OTHERWISE NOTED: THE FOLLOWING SPECIFICATIONS APPLY FOR VCC = +3.0V TO +3.6V WITH TA =
+25OC AND ALL MIN AND MAX LIMITS APPLY ACROSS THE RECOMMENDED OPERATING TEMPERATURE RANGE.
SYMBOL
IOZ
PARAMETERS
Tri-state Output Leakage Current
ISC
Output Short Circuit Current
IOFF
Output Leakage Current Power Off
IOFF
Output Leakage Current Power Off
Switching Characteristics
tPLHD, tPHLD Propagation Delays
tSKEW
Skew, SP26LV431C_
tSKEW
Skew, SP26LV431E_
tTLH, tTHL Differential Output Rise/Fall Times
tPZH
Output Enable Time
tPZL
Output Enable Time
tPHZ
Output Disable Time
tPLZ
Output Disable Time
CPD
Power Dissipation Capacitance
CIN
Input Capacitance
MIN.
-30
TYP.
±2.0
MAX. UNITS
CONDITIONS
uA VOUT = VCC or GND,
ENABLE = VIL, ENABLE = VIH
-150 mA VIN = VCC or GND, Notes 1 & 3
100 uA VCC = 0V, VOUT = 6V, Note 1
-100
uA VCC = 0V, VOUT = -0.25V, Note
1
11
18 ns Figure 5
0.8
2
ns Figure 5, Note 4,
3
ns Figure 5, Note 4
4
10 ns Figure 5
40 ns Figure 7
40 ns Figure 7
35 ns Figure 7, Note 5
35 ns Figure 7, Note 5
50
pF Note 6
6
pF
NOTE:
1.
2.
3.
4.
5.
6.
Refer to EIA specifications for RS-422 serial protocol for exact test conditions.
Measured per input. All other inputs at VCC or GND.
This is the current sourced when a high output is shorted to GND. Only one output at a time should be shorted.
Skew is defined as the difference in propagation delays between complementary outputs at the 50% input.
Output disable time is the delay from ENABLE or ENABLE being switched to the output transistors turning off.
The actual disable times are less than indicated due to the delay added by the RC time constant of the load.
CPD determines the no load dynamic power consumption, PD = (CPDVCC2f) + (ICCVCC), and the no load dynamic
power consumption, IS = (CPDVCCf) + ICC.
5