English
Language : 

XR33032 Datasheet, PDF (4/19 Pages) Exar Corporation – WIDE SUPPLY 18V TOLERANT RS-485/RS-422 TRANSCEIVERS
XR33032/35/38
WIDE SUPPLY 18V TOLERANT RS-485/RS-422 TRANSCEIVERS
REV. 1.0.0
Unless otherwise noted: VCC = +2.8V to +5.5V, TA = -40C to +85C. Typical values are at VCC = 3.3V, TA = +25°C.
SYMBOL
PARAMETERS
MIN. TYP. MAX. UNITS
CONDITIONS
DRIVER THERMAL CHARACTERISTICS
TTS
Thermal Shutdown Temperature
TTSH
Thermal Shutdown Hysteresis
175
°C Junction temperature
15
°C
RECEIVER DC CHARACTERISTICS
Receiver Differential Input Threshold
VTH
Voltage (VA - VB)
-200
VOH
Receiver Input Hysteresis
VOH
Receiver Output High Voltage (RO) VCC-0.6
VOL
Receiver Output Low Voltage (RO)
IOZR
High-Z Receiver Output Current
RIN
Receiver Input Resistance
96
IOSC
Receiver Output Short-Circuit
Current
-125
25
-50
0.4
±1
±120
mV -7V  VCM  +12V
mV VCM = 0V
V IOUT = -1mA
V IOUT = 1mA
µA 0V  VOUT  VCC
k -7V  VCM  +12V
mA 0V  VRO  VCC
SUPPLY CURRENT
ICC
Supply Current
ISHDN
Supply Current in Shutdown Mode
400 600
300 600
300 500
0.040 1
µA No Load, RE = 0V, DE = VCC
DI = 0V
µA No Load, RE = VCC, DE = VCC
DI = 0V
No Load, RE = 0V, DE = 0V
µA
Receiver A and B inputs open
µA RE = VCC, DE = 0V
ESD PROTECTION
±15
ESD Protection for A, B, Y, and Z
±15
±8
ESD Protection for all other pins
±4
kV Human Body Model
kV IEC 61000-4-2 Airgap
kV IEC 61000-4-2 Contact
kV Human Body Model
4