English
Language : 

XR16M2751 Datasheet, PDF (36/52 Pages) Exar Corporation – HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE
XR16M2751
PRELIMINARY
HIGH PERFORMANCE DUART WITH 64-BYTE FIFO AND POWERSAVE FEATURE
P1.0.0
FCTR[2]: IrDa RX Inversion
• Logic 0 = Select RX input as encoded IrDa data (Idle state will be LOW).
• Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be HIGH).
FCTR[3]: Auto RS-485 Direction Control
• Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
becomes empty and transmit shift register is shifting data out.
• Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its
output logic state from LOW to HIGH one bit time after the last stop bit of the last character is shifted out.
Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The
RTS# output pin will automatically return to a LOW when a data byte is loaded into the TX FIFO. However,
RTS# behavior can be inverted by setting EMSR[3] = 1.
FCTR[5:4]: Transmit/Receive Trigger Table Select
See Table 11 for more details.
TABLE 15: TRIGGER TABLE SELECT
FCTR
BIT-5
FCTR
BIT-4
TABLE
0
0 Table-A (TX/RX)
0
1 Table-B (TX/RX)
1
0 Table-C (TX/RX)
1
1 Table-D (TX/RX)
FCTR[6]: Scratchpad Swap
• Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode.
• Logic 1 = FIFO Level Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of
characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced
Mode Select Register is selected when it is written into.
FCTR[7]: Programmable Trigger Register Select
If using both programmable TX and RX trigger levels, TX trigger levels must be set before RX trigger levels.
• Logic 0 = Registers TRG and FC selected for RX.
• Logic 1 = Registers TRG and FC selected for TX.
4.19 Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive
character software flow control selection (see Table 16). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes
are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that
whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before
programming a new setting.
EFR[3:0]: Software Flow Control Select
Single character and dual sequential characters software flow control is supported. Combinations of software
flow control can be selected by programming these bits.
36