English
Language : 

SP334CT-L-TR Datasheet, PDF (3/14 Pages) Exar Corporation – Programmable RS-232/RS-485 Transceiver
SPECIFICATIONS
Limits are specifed at TA = 25°C and VCC = +5.0V unless otherwise
PARAMETER
MIN.
TYP.
RS-232 RECEIVER (continued)
AC Characteristics
Maximum Data Rate
120
235
MAX. UNITS CONDITIONS
kbps
Propagation Delay tPHL
Propagation Delay tPLH
RS-485 DRIVER
0.25
1
0.25
1
µs Measured from 50% of VIN to 1.5V
µs
of VOUT
DC Characteristics
Open circuit Voltage
6.0
Volts
Differential Output
1.5
Balance
Common-Mode Output
5.0
+/-0.2
3.0
Volts
Volts
Volts
RL = 54Ω, CL = 50pF
|VT| - |VT|
Output Current
28.0
mA RL = 54Ω
Short Circuit Current
+/-250 mA Terminated in -7V to +10V
AC Characteristics
Maximum Data Rate
Maximum Data Rate
Output Transition Time
10
30
Mbps RL = 54Ω
8
Mbps RL = 54Ω, TA = +85°C, Note 1
ns Rise/Fall time, 10%-90%
Propagation Delay tPHL
Propagation Delay tPLH
Driver Output Skew
RS-485 RECEIVER
80
120
ns See Figures 3 & 5, RDIFF = 54Ω,
80
120
ns
CL1 = CL2 = 100pF
5
20
ns
Per Figure 5, tSKEW = |tDPHL - tDPLH|
DC Characteristics
Common Mode Range
-7.0
+12 Volts
Receiver Sensitivity
Input Impedance
AC Characteristics
+/-0.2 Volts -7V ≤ VCM ≤ +12V
12
15
kΩ -7V ≤ VCM ≤ +12V
Maximum Data Rate
10
Mbps
Maximum Data Rate
Propagation Delay tPHL
Propagation Delay tPLH
Differential Receiver Skew
ENABLE TIMING
8
Mbps TA = +85°C, Note 1
130
200
ns See Figures 3 & 7, RDIFF = 54Ω,
130
200
ns
CL1 = CL2 = 100pF
10
20
ns
tSKEW = |tPHL - tPLH|, RDIFF = 54Ω,
CL1 = CL2 = 100pF, see Figure 8
RS-485 DRIVER
Enable Time (see Figures 4 and 6)
Enable to LOW
Enable to HIGH
100
150
ns CL = 15pF, S1 Closed
100
150
ns CL = 15pF, S2 Closed
Note 1: Exceeding the maximum data rate of 8Mbps at TA = 85°C may damage the device.
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • 510-668-7017 • www.exar.com

SP334_100_090909