English
Language : 

XRP2997 Datasheet, PDF (2/8 Pages) Exar Corporation – 2A DDR I/II/III Bus Termination Regulator
XRP2997
2A DDR I/II/III Bus Termination Regulator
ABSOLUTE MAXIMUM RATINGS
These are stress ratings only and functional operation of
the device at these ratings or any other above those
indicated in the operation sections of the specifications
below is not implied. Exposure to absolute maximum
rating conditions for extended periods of time may affect
reliability.
VIN, VREF, VCNTL .......................................... -0.3V to 6.0V
Junction Temperature Range..................-40°C to +150°C
Storage Temperature ............................ -65°C to +150°C
Lead Temperature (Soldering, 10 sec) ................... 260°C
OPERATING RATINGS
Operating Temperature Range ................. -40°C to +85°C
Thermal Resistance θJA ...................................... 60°C/W
Thermal Resistance θJC ...................................... 16°C/W
ELECTRICAL SPECIFICATIONS
Specifications are for an Operating Ambient Temperature of TA = 25°C only; limits applying over the full Operating Junction
Temperature range are denoted by a “•”. Minimum and Maximum limits are guaranteed through test, design, or statistical
correlation. Typical values represent the most likely parametric norm at TA = 25°C, and are provided for reference purposes
only. Unless otherwise indicated, VIN = 1.8V/1.5V, VCNTL = 3.3V, VREF = 0.5xVIN, COUT = 22µF (ceramic), TA= 25°C.
Parameter
VIN, Input Voltage Range
VCNTL, Input Voltage Range
VOUT, Output Voltage
VOS, Output Voltage Offset
∆VLOR, Load Regulation
IQ, Quiescent Current
ICNTL, Operating Current of VCNTL
IREF, Bias Current of VREF
IIL, Current Limit
RDSCHG, Output Discharge
Resistance
Thermal Protection
TSD, Thermal Shutdown
Temperature
Thermal Shutdown Hysteresis
Shutdown Specifications
VTRIGGER, Shutdown Threshold
Min.
1.1
2.375
-20
-20
-20
0
2.4
Typ.
1.8/1.5
3.3
VREF
2
1
3
18
160
30
0.8
Max.
5.5
5.5
+20
+20
+20
90
2.5
1
25
0.2
Units
V
V
V
mV
mV
mV
µA
mA
µA
A
Ω
°C
°C
V
Conditions
Keep VCNTL≥VIN during power on and
power off sequences (note 4)
Keep VCNTL≥VIN during power on and
power off sequences (note 4)
IOUT = 0mA
IOUT = 0mA (note 1)
IOUT = 0.1mA to +2A
IOUT = 0.1mA to -2A
VREF < 0.2V, VOUT = OFF
IOUT = 0mA
VREF = 1.25V
Source: VOUT=0.33xVREF
Sink: VOUT=0.95xVIN (note 3)
VREF=0V, VOUT=0.3V
3.3V ≤ VCNTL ≤ 5V, guaranteed by design
(note 4)
Guaranteed by design
Output ON
VREF = 0V  1.25V
Output OFF
VREF = 1.25V  0V
Note 1: VOS offset is the voltage measurement defined as VOUT subtracted from VREF.
Note 2: Load regulation is measured at constant junction temperature, using pulse testing with a short ON time.
Note 3: Current limit is measured by applying a short duration current pulse.
Note 4: In order to safely operate your system, VCNTL must be > VIN.
© 2011 Exar Corporation
2/8
Rev. 1.0.0