English
Language : 

XR1008 Datasheet, PDF (2/17 Pages) Exar Corporation – 0.5mA, 75MHz Rail-to-Rail Amplifiers
XR1008, XR2008
Absolute Maximum Ratings
Stresses beyond the limits listed below may cause
permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect
device reliability and lifetime.
VS ..................................................................................... 0V to 6V
VIN ............................................................ -VS - 0.5V to +VS +0.5V
Continuous Output Current..................................-30mA to +30mA
Operating Conditions
Supply Voltage Range ...................................................2.5 to 5.5V
Operating Temperature Range ...............................-40°C to 125°C
Junction Temperature ........................................................... 150°C
Storage Temperature Range...................................-65°C to 150°C
Lead Temperature (Soldering, 10s) ......................................260°C
Package Thermal Resistance
θJA (TSOT-5) .....................................................................215°C/W
θJA (SOIC-8) .....................................................................150°C/W
θJA (MSOP-8) .................................................................. 200°C/W
Package thermal resistance (θJA), JEDEC standard, multi-layer
test boards, still air.
ESD Protection
XR1008 (HBM) .........................................................................2kV
XR2008 (HBM) ......................................................................2.5kV
ESD Rating for HBM (Human Body Model).
© 2014 Exar Corporation
2 / 17
exar.com/XR1008
Rev 1B