English
Language : 

XRT73R06 Datasheet, PDF (12/68 Pages) Exar Corporation – SIX CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT
XRT73R06
REV. 1.0.0
áç
SIX CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT
CONTROL AND ALARM INTERFACE
LEAD # SIGNAL NAME TYPE
DESCRIPTION
B7
MRING_0 I Monitor Ring Input - Channel 0:
R6
MRING_1
C14
MRING_2
R14
MRING_3
C6
MRING_4
D14
MRING_5
Monitor Ring Input - Channel 1:
Monitor Ring Input - Channel 2:
Monitor Ring Input - Channel 3:
Monitor Ring Input - Channel 4:
Monitor Ring Input - Channel 5:
The bipolar line output signal from TRING_n is connected to this pin via a 270 Ω
resistor to check for line driver failure.
NOTE: This pin is internally pulled up.
B8
MTIP_0
I Monitor Tip Input - Channel 0:
R7
MTIP_1
C13
MTIP_2
R13
MTIP_3
C7
MTIP_4
D13
MTIP_5
Monitor Tip Input - Channel 1:
Monitor Tip Input - Channel 2:
Monitor Tip Input - Channel 3:
Monitor Tip Input - Channel 4:
Monitor Tip Input - Channel 5:
The bipolar line output signal from TTIP_n is connected to this pin via a 270-
ohm resistor to check for line driver failure.
NOTE: This pin is internally pulled up.
C5
DMO_0
O Drive Monitor Output - Channel 0:
T4
DMO_1
B12
DMO_2
T12
DMO_3
D5
DMO_4
B15
DMO_5
Drive Monitor Output - Channel 1:
Drive Monitor Output - Channel 2:
Drive Monitor Output - Channel 3:
Drive Monitor Output - Channel 4:
Drive Monitor Output - Channel 5:
If MTIP_n and MRING_n has no transition pulse for 128 ± 32 TxCLK_n cycles,
DMO_n goes “High” to indicate the driver failure. DMO_n output stays “High”
until the next AMI signal is detected.
C8
RLOS_0 O Receive Loss of Signal - Channel 0:
T7
RLOS_1
C12
RLOS_2
T11
RLOS_3
B11
RLOS_4
R8
RLOS_5
Receive Loss of Signal - Channel 1:
Receive Loss of Signal - Channel 2:
Receive Loss of Signal - Channel 3:
Receive Loss of Signal - Channel 4:
Receive Loss of Signal - Channel 5:
This output pin toggles "High" if the receiver has detected a Loss of Signal Con-
dition.
9