English
Language : 

ALS-PDIC17-57B-TR8_15 Datasheet, PDF (13/21 Pages) Everlight Electronics Co., Ltd – Digital Ambient Light Sensor
DATASHEET
SMD  I2C Digital Ambient Light Sensor
ALS-PDIC17-57B/TR8
Device Command
There are three command codes are provided for I2C master to control the ambient light sensor. The specific
function corresponding to each command code is elaborate in Table 2.
Command
Code
1xxx_xxxx
(binary code)
0x04
0x08
0x30
Function
Shut-down mode, this is the default state after applying VDD power to the device.
During shut-down mode, users can do the communication test. Except the MSB
must be logic 1, the value written to the command register will not change any
function and can be read back via the I2C bus by issuing Receive Byte Protocol.
Activate the ambient light sensor. The integration time is controlled by I2C
commands, start and stop integration.
Start integration: This command will reset the ADC register to 0x0000 and begin a
new integration.
Stop integration: This command will stop the integration and set the valid bit (D[15])
high.
Table 2 Command Code List
Revi1si3on Copy:rig2ht © 2010, Everlight All Rights Reserved. Release Date : 5.27.2013. Issue No:RDLeSl-e0a00s0e04D9 atRe:e2v.2013-06-0w4w0w8.:e0v6e:r0li7g.h0t.com
LifecyclePhase:
Expired Period: Forever