English
Language : 

P02221B2P Datasheet, PDF (5/6 Pages) Eudyna Devices Inc – 500mW InGaP HBT Amplifier
P02221B2P
500mW InGaP HBT Amplifier
Technical Note
♦Package Drawing
4.5 ± 0.1
(1.7)
1.6+0.15
-0.2
(45º)
φ1.0
± 0.3
0.1 ± 0.05
0.42 ± 0.06
0.42 ± 0.06
0.47 ± 0.06
12 3
0.42+0.03
-0.02
1.5 ± 0.1
1.5 ± 0.08 1.5 ± 0.08
♦Laser Marking
1.65MAX
(0.65)
B
123
**P
A: 0.67+0 -0.1
B: 0.45
A
1.3+0.1
-0
1,2,3: Lot No.
* * P: Product Type
♦Convection Reflow Profile (Recommended)
300
260 ± 5°C
5sec max
200
100
0
0
Time above 230°C
< 45 sec
Preheat:160°C
90 sec
60
120
180
240
Time (sec)
[Note]
The reflow profile is different from the one for Sn-Pb
plating
If you use a soldering iron to attach the devices, please
beware of the followings.
(1) The tip of the iron should be grounded. Or you should
use an iron that is electrostatic discharge proof.
(2) The temperature of the iron tip should be lower than
240°C and the soldering should be completed within 10
seconds.
♦Attention to ESD
Generally, GaAs devices are very sensitive to electrostatic
discharge (ESD). To reduce the ESD damage, please pay
attention to the followings. The devices should be stored
with the electrodes short-circuited by conductive materials.
The workstation and tools should be grounded for safe
dissipation of the static charges in the environment. The
workpeople are to wear anti-static clothing and wrist straps.
For safety reasons, resistance of 10MΩ or so should exist
between workpeople and ground.
♦Moisture Sensitivity Level
The moisture sensitivity level (MSL) of P02221B2P is 1,
which means that the “floor life” is unlimited below 30°C
with relative humidity (Rh) of 85%.
♦Reliability and Environmental Issues
Eudyna’s Yokohama Works, where the devices are
manufactured, has been accredited ISO-14001 since 1999.
We control the toxic materials in our products in accordance
with PRTR regulation.
♦ Lead and Fluoride
To realize Pb-free products, Sn-Bi is used for the lead frame
plating. Any fluoride that has been determined by the
Montreal agreement is not used in the products.
♦ Compliance with RoHS
This product is in compliance with Directive 2002/95/EC of
the European Parliament and of the Council of 27 January
2003 for the restriction of use of certain hazardous
substances in electrical and electronics equipment (RoHS
Directives).
Specifications and information are subject to change without notice.
2005-07
Eudyna Devices Inc. 1,Kanai-cho, Sakae-ku, Yokohama, 244-0845 Japan
Phone : +81-45-853-8150 Fax : +81-45-853-8170 e-mail : www-sales-s@eudyna.com Web Site : www.eudyna.com