GMCR100-6 Datasheet, PDF (1/3 Pages) E-Tech Electronics LTD – SENSIT IVE GAT E SILICON CONTROLLED RECT IFIERS REVERSE BLOCKING THYRISTORS 0. 8A, 400V
ISSUED DATE :2005/09/28
REVISED DATE :2006/03/29B
GMCR100-6
S E NS I T I V E G AT E S I L I CO N CO NT ROL L ED RE CT I F I E RS
REVERSE BLOCKING THYRISTORS 0.8A, 400V
Description
The GMCR100-6 PNPN device is designed for high volume, line-powered applications such as relay and lamp
drivers, small motor controls, gate drivers for larger thyristors, and sensing and detection circuits.
Supplied in an inexpensive plastic TO-92 package which is readily adaptable for use in automatic insertion
equipment.
Features
Ô¦Sensitive Gate Allows Triggering by Microcontrollers and Other Logic Circuits
ԦOn-state Current Rating of 0.8A RMS at 80к
Ô¦High Surge Current Capability 10A
Ô¦Minimum and Maximum Values of IGT, VGT and IH Specified for Ease of Design
ԦImmunity to dV/dt - 20 V/ sec Minimum at 110к
Ô¦Glass-Passivated Surface for Reliability and Uniformity
Package Dimensions
D
E
S1
TO-92
b1
S E A T IN G
PLANE
C
e1
b
e
REF.
A
S1
b
b1
C
Millimeter
Min. Max.
4.45
4.7
1.02
-
0.36
0.51
0.36
0.76
0.36
0.51
REF.
D
E
L
e1
e
Millimeter
Min.
Max.
4.44
4.7
3.30
3.81
12.70
-
1.150 1.390
2.42
2.66
Absolute Maximum Ratings (TJ=25к unless otherwise noted)
Rating
Symbol
Value
Unit
Peak Repetitive Off-State Voltage(Note1)
(TJ=-40 to 110к, Sine Wave, 50 to 60Hz; Gate open)
VDRM
VRRM
400
V
On-state RMS Current, (TC=80к) 180шConduction Angles
IT(RMS)
0.8
A
Peak Non-Repetitive Surge Current (1/2 Cycle, Sine Wave, 60Hz, TJ=25к)
ITSM
10
A
Circuit Fusing Consideration (t=8.3ms)
I2t
0.415
A2S
Forward Peak Gate Power (TA=25к, Pulse Width 1.0 s)
PGM
100
mW
Forward Average Gate Power (TA=25к, t=8.3ms)
PG(AV)
10
mW
Forward Peak Gate Current (TA=25к, Pulse Width 1.0 s)
IGM
1.0
A
Reverse Peak Gate Voltage (TA=25к, Pulse Width 1.0 s)
VGRM
5.0
V
Operating Junction Temperature Rang @ Rate VRRM and VDRM
TJ
-40 ~ +110
к
Storage Temperature Rage
Tstg
-40 ~ +150
к
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress
limit values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device function operation is
not implied, damage may occur and reliability may be affected.
Note 1.VDRM and VRRM for all types can be applied on a continuous basis. Ratings apply for zero or negative gate voltage:
however, positive gate voltage shall not be applied concurrent with negative potential on the anode. Blocking voltages shall
not be tested with a constant current source such that the voltage ratings of the devices are exceeded.
GMCR100-6
Page: 1/3